VitroScreen Seminar - Substance-based medical device qualification and classification: Pre-clinical approaches to mechanism of action

Main Article Content

Marisa Meloni, Laura Brambilla, Francesco Carriero, Alessia Frabetti, Maria Grazia Leone, Giulia Magri, Chiara Novi, Christian Pellevoisin, Alessandra Sepe, Alessandra Semenzato, Laura Ceriotti
[show affiliations]

Article Details

How to Cite
Meloni, M. (2023) “VitroScreen Seminar - Substance-based medical device qualification and classification: Pre-clinical approaches to mechanism of action”, ALTEX - Alternatives to animal experimentation, 40(3), pp. 549–552. doi: 10.14573/altex.2303301.
Section
Meeting Reports
References

dimensional human buccal oral mucosal model Toxicol In Vitro 87, 105519. doi:10.1016/j.tiv.2022.105519

Ayehuni, S., Wang, Y.-Y., Landry, T. et al. (2018). Hyperosmolal vaginal lubricants markedly reduce epithelial barrier T properties in a three-dimensional vaginal epithelium model. Toxicol Rep 5, 134-140. doi:10.1016/j.toxrep.2017.12.011

Casiraghi, A., Ranzini, F., Musazzi, U. M. et al. (2017). In vitro method to evaluate the barrier properties of medical devices for cutaneous use. Regul Toxicol Pharmacol 90, 42e50. doi:10.1016/j.yrtph.2017.08.007

Ceriotti, L., Buratti, P., Corazziari, E.C. et al. (2022). Protective mechanisms of liquid formulations for gastro-oesophageal reflux disease in a human reconstructed oesophageal epithelium model. Med Devices 15, 143-152. doi:10.2147/MDER.S363616

Leone, M. G. (2022). Medical devices made of substances: A new challenge. Front Drug Saf Regul 2, 952013. doi:10.3389/fdsfr.2022.952013

Meloni, M., Balzaretti, S. and Ceriotti, L. (2019). Medical devices biocompatibility assessment on HCE: Evidences of delayed cytotoxicity of preserved compared to preservative free eye drops. Regul Toxicol Pharmacol 106, 81-89. doi:10.1016/j.yrtph.2019.04.022

Meloni, M., Buratti, P., Carriero, F. et al. (2021). In vitro modelling of barrier impairment associated with gastro-oesophageal reflux disease (GERD). Clin Exp Gastroenterol 14, 361-373. doi:10.2147/CEG.S325346

Sica, V. P., Friberg, M. A., Teufel, A. G. et al. (2022). Safety assessment scheme for menstrual cups and application for the evaluation of a menstrual cup comprised of medical grade silicone. eBioMedicine 86, 104339. doi:10.1016/j.ebiom.2022.104339

Yang, S.-Y., Piao, Y.-Z, Kim, K.-M. et al. (2021). Cytokine release from organotypic human oral tissue following exposure to oral care product chemicals. J Korean Dent Sci 14, 51-60.

Yun, J. W., Hailian, Q., Na, Y. et al. (2016). Exploration and comparison of in vitro eye irritation tests with the ISO standard in vivo rabbit test for the evaluation of the ocular irritancy of contact lenses. Toxicol In Vitro 37, 79-87. doi:10.1016/j.tiv.2016.09.001

Most read articles by the same author(s)